Gates & Fencing · Acton

Driveway Gates in Acton, CA

A driveway gate in Acton is built to the grade of the drive and to the load of an operator you may add later. We weld the frame in our shop and fit any name span inside the county's ranch entrance limits.

Grade picks the gate type before looks do. Plenty of drives in Acton leave the road and climb. A pair of swing leaves opens into the property, which on a rising drive means uphill, and the bottom rail meets the pavement partway through its arc. A slide gate moves across the slope instead of into it. It needs a clear run beside the opening to park the leaf, roughly the gate width again. When the road end of the drive has room for neither, the gate can move up to flatter ground, and we lay that out with you at the measure.

Where the gate sits also sets how tall it can be. Acton falls under Los Angeles County zoning, and LA County Code 22.110.070 caps a fence at 3 feet 6 inches inside a required front yard and at 6 feet in an interior side or rear yard. Height is taken from the highest average ground level within 3 feet of either side. A tall leaf right at the road lands inside the front yard figure. Ask county planning how that section treats a gate and its posts on your parcel before we size the leaf, because the answer fixes every length we cut.

The Acton Community Standards District puts its own layer on top. Under 22.302.060.G a perimeter fence has to be split rail, open wood, wire, or wrought iron style, or a similar open type, with exceptions the section names, and at least 70 percent of the fence area has to stay open to view. A driveway gate usually stands in that perimeter line. How a solid steel leaf there gets counted is a question for county planning before you commit to one. An open picket leaf in the wrought iron style keeps clear of the question, and it catches far less wind, so the posts and hinges carry less.

If you want the ranch name over the drive, the district sets the envelope. Section 22.302.060.F.2.c allows one residential ranch entrance sign span per lot. Its top may not stand more than 20 feet above natural grade, and the sign faces together are held to 12 square feet. We fabricate the uprights, the crossbar and the gate as one design, so the span clears the tallest thing that uses the drive and still fits those limits. Measure your tallest truck or trailer before we come out.

The frame is welded steel tube cut to the opening we measure. A leaf hangs off one post like a lever, so post and hinge sizes climb as the leaf widens, out to 4 inch square gate posts on the widest leaves. A single swing leaf runs to roughly 16 feet in what this shop builds. Wider openings split into two leaves. We set gate posts at least 36 inches into concrete and deeper under a wide or solid leaf. That number is our shop practice, not a code minimum.

A gate a long way from the house is a natural candidate for a motor, now or years from now. We size the hinges and posts for the load an operator adds, weld a mounting plate into the frame, and run a sleeve through the post so wiring has a path through the steel. UL 325 and ASTM F2200 leave a manual gate alone, but both apply the day it is motorized. The operator, its electronics and its wiring belong to other trades. Our part is the steel they mount to.

This work runs out of our shop on Division Street in Lancaster. Read the full driveway gates details, or call (818) 220-8704 and we will come out.

FAQ

Questions about driveway gates in Acton

Can I put a solid steel driveway gate on an Acton property?

Possibly, but ask before you order one. The Acton Community Standards District limits a perimeter fence under 22.302.060.G to split rail, open wood, wire, or wrought iron style, or a similar open type, with named exceptions, and requires at least 70 percent of the fence area to be non-view-obscuring. A gate in the perimeter line may be read as part of that fence. County planning can tell you how they count it on your parcel. An open picket leaf is built in the wrought iron style the section lists.

Does the size of my lot change what the gate can be?

It can. The list of open fence types in 22.302.060.G carries an exception for residential lots under 10,000 square feet, and another where a view-obscuring fence is required for screening elsewhere in Title 22. Pull the lot area from your parcel records before you talk to planning or to us. Whether the 70 percent test also relaxes on a small lot belongs on your list of questions for planning.

How tall can the gate be where the drive meets the road?

If the gate stands inside the required front yard, LA County Code 22.110.070 holds a fence there to 3 feet 6 inches, measured from the highest average ground level within 3 feet of either side. That is short for a ranch gate. Setting the gate back up the drive, behind the setback, takes it out of the front yard figure. Confirm with county planning how the section reads for a gate at your address.

Swing or slide on a drive that rises from the road?

Two swing leaves need arc space inside the property and a drive close to level at the opening, so on a rising drive the bottom rail can drag before the leaf is fully open. A slide gate clears the grade where a swing leaf would drag, but it needs a clear run beside the opening of roughly the gate width again to park the leaf. We look at both on site and tell you which one your opening allows.

Can a name span go over the gate posts?

Yes, inside the district limits. Section 22.302.060.F.2.c allows one residential ranch entrance sign span per lot, with the top no more than 20 feet from natural grade and no more than 12 square feet of combined sign face. Because it is one span per lot, choose which entrance gets it. We build the span and the gate together so the uprights are sized for both.

What drives the cost of an Acton driveway gate?

Width first, because a wider leaf needs a heavier post, heavier hinges and sometimes a second leaf. Then the infill, since a solid face is more steel than pickets and loads the post harder. A slope adds work, whether that means a slide track or a frame cut to the grade. A name span, operator prep and the coated area of the finish come after that. We price after the measure, not before.

What should I have ready when you come out to measure?

The lot area, and roughly where the property line and the front setback sit. Whether you want a motor now, later or never, and where power could reach the gate. The height of the tallest vehicle or trailer on the drive if a span is planned. Photos looking down the drive from the house and up it from the road.

Who pulls the permit for a new gate in Acton?

The property owner or the contractor of record. Los Angeles County decides whether the gate, the posts or a ranch entrance span needs a permit at all. We tell you the post sections, the footing and the leaf dimensions we plan, so what goes on the paperwork matches the steel that goes in the ground.

Should a manual gate be built ready for a motor?

If there is any chance of one, yes. Adding an operator to a frame that was never sized for it usually means reworking the frame, the hinges or the posts first. Built ready, the leaf already has a mounting plate, a wiring sleeve and hinges sized for the extra load. From the day it is motorized, UL 325 and ASTM F2200 apply, so the frame is built with them in mind.

What changes on a slide gate that later gets an operator?

On Classes I, II and III, ASTM F2200 then wants guards on exposed weight bearing rollers 8 feet or less above grade, positive stops at both ends of travel, and screening so a 2.25 inch sphere cannot pass the gate or the fence it covers when open, up to 72 inches above grade or the top of a shorter gate. Our standard picket gap is near 3.25 inches, so the leaf and that stretch of fence both need tighter infill. Tighter infill is less open to view, so raise how it counts against the district's 70 percent rule with county planning.

Which finish holds up at the end of an open drive?

Hot dip galvanizing to ASTM A123, where coating thickness follows the thickness of the steel, then powder over it. The American Galvanizers Association puts that duplex system at roughly 1.5 to 2.3 times the combined life of the two coatings alone. The prep in ASTM D7803 keeps pinholes out of the powder. For color, ask for an AAMA 2604 class powder rather than the basic 2603 tier.

Can you rebuild my old gate rather than start over?

Often. A lot of what we work on is steel somebody else built. Racked frames get squared, worn hinges get cut out and replaced, a rotted bottom rail gets rebuilt, and a leaf that has dropped at the latch gets a brace. If the posts have moved, that gets corrected before the leaf is rehung, or the same sag comes back.

Need driveway gates in Acton?

Free estimates. We come measure the opening or the property line first.